By using this site, you agree to the Privacy Policy and Terms of Use.
Accept
Health Works CollectiveHealth Works CollectiveHealth Works Collective
  • Health
    • Mental Health
    Health
    Healthcare organizations are operating on slimmer profit margins than ever. One report in August showed that they are even lower than the beginning of the…
    Show More
    Top News
    bowl of vegetable salad
    Raw Foods: benefits and harms
    November 9, 2021
    pros and cons of the keto diet
    Read This Before You Follow the Keto Diet
    May 18, 2022
    spinal cord injuries
    4 Potential Causes of Spinal Cord Injuries (and How to Seek Compensation)
    May 25, 2022
    Latest News
    Beyond Nutrition: Everyday Foods That Support Whole-Body Health
    June 15, 2025
    The Wide-Ranging Benefits of Magnesium Supplements
    June 11, 2025
    The Best Home Remedies for Migraines
    June 5, 2025
    The Hidden Impact Of Stress On Your Body’s Alignment And Balance
    May 22, 2025
  • Policy and Law
    • Global Healthcare
    • Medical Ethics
    Policy and Law
    Get the latest updates about Insurance policies and Laws in the Healthcare industry for different geographical locations.
    Show More
    Top News
    The key stakeholders involved in improving healthcare policy
    The Key Stakeholders involved in Improving Healthcare Policy
    October 26, 2023
    medical erros avoid
    How to Report Medication Errors and Why It’s Important
    November 17, 2024
    Essential Steps for Developing a Life Care Plan
    Essential Steps for Developing a Life Care Plan
    December 26, 2024
    Latest News
    Top HIPAA-Compliant Messaging Apps for Healthcare Teams
    June 25, 2025
    When Healthcare Ends, the Legal Process Begins: What Families Should Know About Probate and Medical Estates
    June 20, 2025
    Preventing Contamination In Healthcare Facilities Starts With Hygiene
    June 15, 2025
    Strengthening Healthcare Systems Through Clinical and Administrative Career Development
    June 13, 2025
  • Medical Innovations
  • News
  • Wellness
  • Tech
Search
© 2023 HealthWorks Collective. All Rights Reserved.
Reading: Medical Device Connectivity: Lessons from a Recent Recall
Share
Notification Show More
Font ResizerAa
Health Works CollectiveHealth Works Collective
Font ResizerAa
Search
Follow US
  • About
  • Contact
  • Privacy
© 2023 HealthWorks Collective. All Rights Reserved.
Health Works Collective > Technology > Medical Devices > Medical Device Connectivity: Lessons from a Recent Recall
Medical DevicesMobile HealthNewsTechnology

Medical Device Connectivity: Lessons from a Recent Recall

Tim Gee
Last updated: December 19, 2011 8:34 am
Tim Gee
Share
7 Min Read
SHARE

A recent Class I recall of a medical monitor with a hospital network connected central station stimulates some generalities about software, “fixes”, and connectivity.

A recent Class I recall of a medical monitor with a hospital network connected central station stimulates some generalities about software, “fixes”, and connectivity. (Class I recalls are defined by the FDA as  a situation in which there is a reasonable probability that the use of, or exposure to, a violative product will cause serious adverse health consequences or death.)

The use of the product in question was given as:

  • a networked solution system used to monitor a patient’s vital signs and therapy, control alarms, review Web-based diagnostic images, and access patient records. The number of monitored vital signs can be increased or decreased based on the patient’s needs

Curiously only one customer was identified as having received the product, or at least this particular version of the product. While the manufacturer and product in question is a matter of public record, and available at the link, I chose not to include it here because my objective is not to repeat the recall information, but to suggest the reasons for the recall, an associated labeling issue, and offer some general lessons. 

More Read

Mosquito-Dissecting Robot May Bring Malaria Vaccine Closer to Reality
Wound Closure Market Shifts From Traditional to Advance Products
MD Connect Drives 250,000th Digital Referral In Vein Market
Quote of the Day
How Technology Is Affecting Healthcare

The reason given for the recall had two seemingly separate parts. The first is that “The weight-based drug dosage calculation may indicate incorrect recommended values, including a drug dosage up to ten times the indicated dosage”. This sounds like a software problem yet the fix was not to “upgrade” the software but to suggest a workaround. (I love the term upgrade to when applied to fixing something that doesn’t actually work!)  According to the FDA the firm’s letter stated that “users should enter the patient’s weight by way of the admin/demographics screen to ensure the drug dosage is calculated as intended.” (I did not find the firm’s letter on its website, but it might be one of those hidden page situations since I did find, with a struggle, two other recalls, though using the search term “recall” produced no results). Again speculating, the workaround sounds like a user dependent way to do something that was supposed to happen automatically. At least part of the value of automation is largely diminished, and opportunities for use error increased, when such additional demands are placed on the user.

The second reason given for the recall was that there may be a 5-10 second delay between the electrocardiogram and blood pressure curves (waveforms) at the central station.   This is an interesting technical issue that may be related to software and/or communication protocols. In either case it illustrates that multiple data streams may only be useful if they are properly timed stamped, and then properly aligned at the receiver. Out-of-sync data when subsequently processed either by eye, or automatically, can give erroneous and misleading results that might appear to be correct, i.e. the results could be in the category of erroneous but believable.

For one or both reasons the FDA found that, “This product may cause serious adverse health consequences, including death.” Yet it should be noted that this was a voluntary recall, as most recalls are, despite the fact that people who surely know better reported this as “FDA recalls…”

The FDA announcement goes on to say that the company pointed out that the instructions for use state that: ”For primary monitoring and diagnosis of bedside patients, use the bedside monitor. Use the…Central Station only for remote assessment of a patient’s status.” This sentence seems to be illustrative of the fundamental problem of remote information receivers and integrators that carry a disclaimer that in sum says that you shouldn’t rely on them. But isn’t the ability to rely on it exactly why you bought it? Moreover, promotional materials available on the web do not appear to echo this disclaimer. For example it is stated that ”Applications…enhance patient care management by providing rapid assessment, decision support and clinical reporting.” Does that sound like it isn’t for primary diagnosis? Or does “Data accessible from the…Central Station includes real-time waveforms” sound like those waveforms shouldn’t be used for primary monitoring? For one more example it is said that “arrhythmia events are detected with an unprecedented degree of accuracy.” Accuracy is certainly a good thing, but detecting arrhythmias at the central station when only the beside monitor is to be used for “primary monitoring and diagnosis” appears to be less than highly useful.

Furthermore the statement that the central station is only for remote assessment seems both definitional and contradictory. It is obviously for remote assessment–because it is a central station and thus remote! But then what does “assessment of the patient’s status” mean if not monitoring and diagnosis?

The disclaimer game has been addressed in these pages before. Here it seems to involve a product that is being marketed, sold and bought for exactly the reasons that the manufacturer is saying it shouldn’t be used. I didn’t spot the disclaimer language in any of the promotional materials, but maybe it is there somewhere.

So, we have here an apparent example of software driven miscalculations, network transported data that is not time synchornized, and a reminder not to use the central station for primary assessment. Important examples to remember as we charge ahead with software driven networked solutions.

[The products in the photo with this post above are not associated with the recall discussed, and are for illustrative purposes only.]

William Hyman is Professor Emeritus of the Department of Biomedical Engineering at Texas A&M University. He recently retired and has moved to New York City where he continues his professional activities.

 

 

 

TAGGED:FDAmedical device connectivityproduct recall
Share This Article
Facebook Copy Link Print
Share

Stay Connected

1.5kFollowersLike
4.5kFollowersFollow
2.8kFollowersPin
136kSubscribersSubscribe

Latest News

women dental care
What Is a Smile Makeover and How Much Does It Cost?
Dental health
June 30, 2025
HIPAA-Compliant Messaging Apps
Top HIPAA-Compliant Messaging Apps for Healthcare Teams
Global Healthcare Policy & Law Technology
June 25, 2025
recovering from injury
Rebuilding After Injury: Path to Physical and Emotional Recovery
News
June 22, 2025
scientist using microscope
When Healthcare Ends, the Legal Process Begins: What Families Should Know About Probate and Medical Estates
Global Healthcare
June 18, 2025

You Might also Like

How Pharma Companies Can Become Bigger Players in Mobile Health

August 13, 2013

Jan Medical – Breakthrough Study in Stroke Detection

April 2, 2011
minimize effects of smoking
Health

Strategies for Active Smokers Trying to Minimize Harm

April 13, 2023
Technology

5 Ways Tech Will Change The Health And Fitness Industry In The Future

April 7, 2020
Subscribe
Subscribe to our newsletter to get our newest articles instantly!
Follow US
© 2008-2025 HealthWorks Collective. All Rights Reserved.
  • About
  • Contact
  • Privacy
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?