By using this site, you agree to the Privacy Policy and Terms of Use.
Accept
Health Works CollectiveHealth Works CollectiveHealth Works Collective
  • Health
    • Mental Health
    Health
    Healthcare organizations are operating on slimmer profit margins than ever. One report in August showed that they are even lower than the beginning of the…
    Show More
    Top News
    photo of hands with blue veins
    8 Proven Tips on Finding Difficult Veins
    November 12, 2021
    tips for getting over the pandemic blues
    4 Proven Ways to Get Over the Pandemic Blues
    February 22, 2022
    medical industry innovations
    How is CNC Machining Transforming the Medical Industry?
    June 2, 2022
    Latest News
    The Wide-Ranging Benefits of Magnesium Supplements
    June 11, 2025
    The Best Home Remedies for Migraines
    June 5, 2025
    The Hidden Impact Of Stress On Your Body’s Alignment And Balance
    May 22, 2025
    Chewing Matters More Than You Think: Why Proper Chewing Supports Better Health
    May 22, 2025
  • Policy and Law
    • Global Healthcare
    • Medical Ethics
    Policy and Law
    Get the latest updates about Insurance policies and Laws in the Healthcare industry for different geographical locations.
    Show More
    Top News
    Transformational and Disruptive Changes Are Coming to the Delivery System
    July 22, 2012
    Telemedicine and the PCP Cliff
    November 30, 2012
    Engaging Specialty Practices in the Patient Centered Medical Neighborhood
    March 24, 2013
    Latest News
    Streamlining Healthcare Operations: How Our Consultants Drive Efficiency and Overall Improvement
    June 11, 2025
    Building Smarter Care Teams: Aligning Roles, Structure, and Clinical Expertise
    May 18, 2025
    The Critical Role of Healthcare in Personal Injury Recovery: A Comprehensive Guide for Victims
    May 14, 2025
    The Backbone of Successful Trials: Clinical Data Management
    April 28, 2025
  • Medical Innovations
  • News
  • Wellness
  • Tech
Search
© 2023 HealthWorks Collective. All Rights Reserved.
Reading: Medical Device Connectivity: Lessons from a Recent Recall
Share
Notification Show More
Font ResizerAa
Health Works CollectiveHealth Works Collective
Font ResizerAa
Search
Follow US
  • About
  • Contact
  • Privacy
© 2023 HealthWorks Collective. All Rights Reserved.
Health Works Collective > Technology > Medical Devices > Medical Device Connectivity: Lessons from a Recent Recall
Medical DevicesMobile HealthNewsTechnology

Medical Device Connectivity: Lessons from a Recent Recall

Tim Gee
Last updated: December 19, 2011 8:34 am
Tim Gee
Share
7 Min Read
SHARE

A recent Class I recall of a medical monitor with a hospital network connected central station stimulates some generalities about software, “fixes”, and connectivity.

A recent Class I recall of a medical monitor with a hospital network connected central station stimulates some generalities about software, “fixes”, and connectivity. (Class I recalls are defined by the FDA as  a situation in which there is a reasonable probability that the use of, or exposure to, a violative product will cause serious adverse health consequences or death.)

The use of the product in question was given as:

  • a networked solution system used to monitor a patient’s vital signs and therapy, control alarms, review Web-based diagnostic images, and access patient records. The number of monitored vital signs can be increased or decreased based on the patient’s needs

Curiously only one customer was identified as having received the product, or at least this particular version of the product. While the manufacturer and product in question is a matter of public record, and available at the link, I chose not to include it here because my objective is not to repeat the recall information, but to suggest the reasons for the recall, an associated labeling issue, and offer some general lessons. 

More Read

How to Use Instagram Video in Healthcare
Changing Fortunes in the Obesity Treatment Industry
The Consumer-Driven, Digital Disruption in Healthcare
Using Open Source Software in Safety-Critical Medical Devices
Marketing Automation, Oh My! Lessons from a Leading Health System

The reason given for the recall had two seemingly separate parts. The first is that “The weight-based drug dosage calculation may indicate incorrect recommended values, including a drug dosage up to ten times the indicated dosage”. This sounds like a software problem yet the fix was not to “upgrade” the software but to suggest a workaround. (I love the term upgrade to when applied to fixing something that doesn’t actually work!)  According to the FDA the firm’s letter stated that “users should enter the patient’s weight by way of the admin/demographics screen to ensure the drug dosage is calculated as intended.” (I did not find the firm’s letter on its website, but it might be one of those hidden page situations since I did find, with a struggle, two other recalls, though using the search term “recall” produced no results). Again speculating, the workaround sounds like a user dependent way to do something that was supposed to happen automatically. At least part of the value of automation is largely diminished, and opportunities for use error increased, when such additional demands are placed on the user.

The second reason given for the recall was that there may be a 5-10 second delay between the electrocardiogram and blood pressure curves (waveforms) at the central station.   This is an interesting technical issue that may be related to software and/or communication protocols. In either case it illustrates that multiple data streams may only be useful if they are properly timed stamped, and then properly aligned at the receiver. Out-of-sync data when subsequently processed either by eye, or automatically, can give erroneous and misleading results that might appear to be correct, i.e. the results could be in the category of erroneous but believable.

For one or both reasons the FDA found that, “This product may cause serious adverse health consequences, including death.” Yet it should be noted that this was a voluntary recall, as most recalls are, despite the fact that people who surely know better reported this as “FDA recalls…”

The FDA announcement goes on to say that the company pointed out that the instructions for use state that: ”For primary monitoring and diagnosis of bedside patients, use the bedside monitor. Use the…Central Station only for remote assessment of a patient’s status.” This sentence seems to be illustrative of the fundamental problem of remote information receivers and integrators that carry a disclaimer that in sum says that you shouldn’t rely on them. But isn’t the ability to rely on it exactly why you bought it? Moreover, promotional materials available on the web do not appear to echo this disclaimer. For example it is stated that ”Applications…enhance patient care management by providing rapid assessment, decision support and clinical reporting.” Does that sound like it isn’t for primary diagnosis? Or does “Data accessible from the…Central Station includes real-time waveforms” sound like those waveforms shouldn’t be used for primary monitoring? For one more example it is said that “arrhythmia events are detected with an unprecedented degree of accuracy.” Accuracy is certainly a good thing, but detecting arrhythmias at the central station when only the beside monitor is to be used for “primary monitoring and diagnosis” appears to be less than highly useful.

Furthermore the statement that the central station is only for remote assessment seems both definitional and contradictory. It is obviously for remote assessment–because it is a central station and thus remote! But then what does “assessment of the patient’s status” mean if not monitoring and diagnosis?

The disclaimer game has been addressed in these pages before. Here it seems to involve a product that is being marketed, sold and bought for exactly the reasons that the manufacturer is saying it shouldn’t be used. I didn’t spot the disclaimer language in any of the promotional materials, but maybe it is there somewhere.

So, we have here an apparent example of software driven miscalculations, network transported data that is not time synchornized, and a reminder not to use the central station for primary assessment. Important examples to remember as we charge ahead with software driven networked solutions.

[The products in the photo with this post above are not associated with the recall discussed, and are for illustrative purposes only.]

William Hyman is Professor Emeritus of the Department of Biomedical Engineering at Texas A&M University. He recently retired and has moved to New York City where he continues his professional activities.

 

 

 

TAGGED:FDAmedical device connectivityproduct recall
Share This Article
Facebook Copy Link Print
Share

Stay Connected

1.5kFollowersLike
4.5kFollowersFollow
2.8kFollowersPin
136kSubscribersSubscribe

Latest News

Streamlining Healthcare Operations: How Our Consultants Drive Efficiency and Overall Improvement
Global Healthcare Policy & Law
June 11, 2025
magnesium supplements
The Wide-Ranging Benefits of Magnesium Supplements
Health
June 11, 2025
Preparing for the Next Pandemic: How Technology is Changing the Game
Technology
June 6, 2025
migraine home remedies and-devices
The Best Home Remedies for Migraines
Health Mental Health
June 5, 2025

You Might also Like

Health Wonk Review: The New Wright on Health Edition

February 2, 2014
eHealthGlobal HealthcareHome HealthMobile Health

Can An Medication Reminder App Boost Adherence?

April 2, 2019

RSNA 2013: President’s Address Encourages Radiologists to Embrace Multidiscinplinary Teams

December 3, 2013

A Victory for Coverage with Evidence Development

September 8, 2011
Subscribe
Subscribe to our newsletter to get our newest articles instantly!
Follow US
© 2008-2025 HealthWorks Collective. All Rights Reserved.
  • About
  • Contact
  • Privacy
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?