    Healthcare organizations are operating on slimmer profit margins than ever. One report in August showed that they are even lower than the beginning of the…
    Show More
    Top News
    stress disorder
    5 Ways To Manage Post-Traumatic Stress Disorder
    October 27, 2021
    Medical device classification and development strategies
    Medical device classification and development strategies
    April 5, 2023
    varicose veins
    Varicose Veins Prevention: 3 Lifestyle Changes to Make Right Now
    May 1, 2022
    Latest News
    Hygiene Beyond The Clinic: Attention To Overlooked Non-Clinical Spaces
    August 13, 2025
    5 Steps to a Promising Career as a Healthcare Administrator
    August 3, 2025
    Why Custom Telemedicine Apps Outperform Off‑the‑Shelf Solutions
    July 20, 2025
    How Probate Planning Shapes the Future of Your Estate and Family Care
    July 17, 2025
  • Policy and Law
    • Global Healthcare
    • Medical Ethics
    Policy and Law
    Get the latest updates about Insurance policies and Laws in the Healthcare industry for different geographical locations.
    Show More
    Top News
    Image
    RN to MSN: 5 Reasons Nurses Should Pursue That Extra Degree
    July 31, 2017
    Lessons from the Anthem Breach
    February 12, 2015
    Working From Home In Healthcare: Can You Adapt To Remote Work?
    July 30, 2019
    Latest News
    How IT and Marketing Teams Can Collaborate to Protect Patient Trust
    July 17, 2025
    How Health Choices and Legal Actions Intersect After an Injury
    July 17, 2025
    How communities and healthcare providers can address slip and fall injuries with legal awareness
    July 17, 2025
    Let Your Lawyer Handle the Work Before You Pay Medical Costs
    July 6, 2025
  • Medical Innovations
  • News
  • Wellness
  • Tech
Search
© 2023 HealthWorks Collective. All Rights Reserved.
Reading: Medical Device Connectivity: Lessons from a Recent Recall
Share
Notification Show More
Font ResizerAa
Health Works CollectiveHealth Works Collective
Font ResizerAa
Search
Follow US
  • About
  • Contact
  • Privacy
© 2023 HealthWorks Collective. All Rights Reserved.
Health Works Collective > Technology > Medical Devices > Medical Device Connectivity: Lessons from a Recent Recall
Medical DevicesMobile HealthNewsTechnology

Medical Device Connectivity: Lessons from a Recent Recall

Tim Gee
Tim Gee
Share
7 Min Read
SHARE

A recent Class I recall of a medical monitor with a hospital network connected central station stimulates some generalities about software, “fixes”, and connectivity.

A recent Class I recall of a medical monitor with a hospital network connected central station stimulates some generalities about software, “fixes”, and connectivity. (Class I recalls are defined by the FDA as  a situation in which there is a reasonable probability that the use of, or exposure to, a violative product will cause serious adverse health consequences or death.)

The use of the product in question was given as:

  • a networked solution system used to monitor a patient’s vital signs and therapy, control alarms, review Web-based diagnostic images, and access patient records. The number of monitored vital signs can be increased or decreased based on the patient’s needs

Curiously only one customer was identified as having received the product, or at least this particular version of the product. While the manufacturer and product in question is a matter of public record, and available at the link, I chose not to include it here because my objective is not to repeat the recall information, but to suggest the reasons for the recall, an associated labeling issue, and offer some general lessons. 

More Read

Partnership With Patients
The Partnership with Patients Agenda
Metabolic/Bariatric Surgery Types
Ethical Considerations and Data Privacy in Retrieval Augmented Generation Systems
Healthcare Costs Involved in Treating Drug Addiction
When is Medicare Open Enrollment 2023? What to Know

The reason given for the recall had two seemingly separate parts. The first is that “The weight-based drug dosage calculation may indicate incorrect recommended values, including a drug dosage up to ten times the indicated dosage”. This sounds like a software problem yet the fix was not to “upgrade” the software but to suggest a workaround. (I love the term upgrade to when applied to fixing something that doesn’t actually work!)  According to the FDA the firm’s letter stated that “users should enter the patient’s weight by way of the admin/demographics screen to ensure the drug dosage is calculated as intended.” (I did not find the firm’s letter on its website, but it might be one of those hidden page situations since I did find, with a struggle, two other recalls, though using the search term “recall” produced no results). Again speculating, the workaround sounds like a user dependent way to do something that was supposed to happen automatically. At least part of the value of automation is largely diminished, and opportunities for use error increased, when such additional demands are placed on the user.

The second reason given for the recall was that there may be a 5-10 second delay between the electrocardiogram and blood pressure curves (waveforms) at the central station.   This is an interesting technical issue that may be related to software and/or communication protocols. In either case it illustrates that multiple data streams may only be useful if they are properly timed stamped, and then properly aligned at the receiver. Out-of-sync data when subsequently processed either by eye, or automatically, can give erroneous and misleading results that might appear to be correct, i.e. the results could be in the category of erroneous but believable.

For one or both reasons the FDA found that, “This product may cause serious adverse health consequences, including death.” Yet it should be noted that this was a voluntary recall, as most recalls are, despite the fact that people who surely know better reported this as “FDA recalls…”

The FDA announcement goes on to say that the company pointed out that the instructions for use state that: ”For primary monitoring and diagnosis of bedside patients, use the bedside monitor. Use the…Central Station only for remote assessment of a patient’s status.” This sentence seems to be illustrative of the fundamental problem of remote information receivers and integrators that carry a disclaimer that in sum says that you shouldn’t rely on them. But isn’t the ability to rely on it exactly why you bought it? Moreover, promotional materials available on the web do not appear to echo this disclaimer. For example it is stated that ”Applications…enhance patient care management by providing rapid assessment, decision support and clinical reporting.” Does that sound like it isn’t for primary diagnosis? Or does “Data accessible from the…Central Station includes real-time waveforms” sound like those waveforms shouldn’t be used for primary monitoring? For one more example it is said that “arrhythmia events are detected with an unprecedented degree of accuracy.” Accuracy is certainly a good thing, but detecting arrhythmias at the central station when only the beside monitor is to be used for “primary monitoring and diagnosis” appears to be less than highly useful.

Furthermore the statement that the central station is only for remote assessment seems both definitional and contradictory. It is obviously for remote assessment–because it is a central station and thus remote! But then what does “assessment of the patient’s status” mean if not monitoring and diagnosis?

The disclaimer game has been addressed in these pages before. Here it seems to involve a product that is being marketed, sold and bought for exactly the reasons that the manufacturer is saying it shouldn’t be used. I didn’t spot the disclaimer language in any of the promotional materials, but maybe it is there somewhere.

So, we have here an apparent example of software driven miscalculations, network transported data that is not time synchornized, and a reminder not to use the central station for primary assessment. Important examples to remember as we charge ahead with software driven networked solutions.

[The products in the photo with this post above are not associated with the recall discussed, and are for illustrative purposes only.]

William Hyman is Professor Emeritus of the Department of Biomedical Engineering at Texas A&M University. He recently retired and has moved to New York City where he continues his professional activities.

 

 

 

TAGGED:FDAmedical device connectivityproduct recall
Share This Article
Facebook Copy Link Print
Share

Stay Connected

1.5kFollowersLike
4.5kFollowersFollow
2.8kFollowersPin
136kSubscribersSubscribe

Latest News

non-clinical spaces
Hygiene Beyond The Clinic: Attention To Overlooked Non-Clinical Spaces
Health Infographics
August 13, 2025
senior care at home
Breaking The Chain Of Infection For Seniors At Home
Infographics Senior Care
August 13, 2025
medical devices
The Lifecycle Of A Medical Device: From Concept To Disposal
Infographics Technology
August 13, 2025
Why Delaying Care For Minor Injuries Can Lead To Bigger Problems
Infographics Wellness
August 13, 2025

You Might also Like

medical device and mHealth
BusinesseHealthMedical DevicesMedical RecordsMobile HealthTechnology

mHealth Practices: Plugging the Holes

June 14, 2013
healthcare technology
Global HealthcareTechnology

5 Underrecognized Technological Breakthroughs in Healthcare

July 16, 2024

Onsite Detection of Malaria Could Be Possible with a Battery-Operated Device

August 8, 2013
digital health
eHealthTechnology

Is Digital Health Helping or Failing Patients? A Conversation Between a Futurist and ePatient